Pneumatic actuators for use with GCV control valves PN9000 series

The PN9000 series actuators are a compact range of linear actuators that are available in four sizes. This range of actuators comprise of four diaphragm sizes for matching the requirements of valves at various differential pressures.

Media Library

English
PDF - Installation instructions

Level electrode NRG 16-11, NRG 17-11, NRG 19-11, NRG 111-11

The water level limiter comprises a level electrode type NRG 1...-11 and a level switch type NRS 1-50. The level electrode NRG 1...-11 consists of two concentrically arranged electrodes (measuring electrode and compensating electrode) which are isolated from each other by special insulating seals.

Media Library

English
PDF - Installation instructions

Logic unit SRL 63-a

For the installation of low-level limiters of “high-integrity design” in measuring pots mounted outside of the boiler, it is imperative that the periodic purging of the connecting lines to the boiler be monitored properly. To achieve this, the connecting lines are shut off one after the other at defined intervals and the measuring pot is drained.

Media Library

English
PDF - Installation instructions

Pneumatic Actuators for use with GCV Control Valves PN9000 Series

The PN9000 series actuators are a compact range of linear actuators that are available in 3 diaphragm sizes for matching the requirements of valves at various differential pressures. Each actuator is fitted with a mechanical travel indicator and incorporates a fully-rolling diaphragm, which provides good linearity over the operating stroke.

Media Library

English
PDF - Data sheets

Level Electrodes NRG 16-60 NRG 17-60 NRG 19-60 NRG 111-60

In combination with the URS 60 / URS 61 safety control unit, NRG 1x-60 level electrodes are suitable for safety functions up to SIL 3. They are elements of a safety circuit up to a rating of SIL 3 as per EN 61508 in the SPECTORconnect system, and can transmit alarm notifications.

Media Library

English
PDF - Data sheets

Logic Unit SRL 6-50

If the level electrode (high or low level limiter) is installed in an isolatable level pot outside the boiler, make sure that the level pot is drained and the connecting lines are rinsed at regular intervals. For this purpose the connecting lines must be shut off and opened at regular intervals and by opening and closing the drain valve the lines and the level pot will be rinsed. The logic unit is designed to be used in conjunction with level switch NRS 1-50 (water level limiter) or level switch NRS 1-51 (high level alarm) to monitor the correct timing and sequence of valve operations. During the rinsing process the level switch jumpers the level electrode, thus preventing the safety or control circuit from opening. The level switch - controlled by the logic unit - also monitors the rinsing and bypass time.

Media Library

English
PDF - Data sheets

Level electrode NRG 16-50S

The level electrode NRG 16-50 S is used in conjunction with level switch NRS 1-50 (de-energizing delay: 15 seconds) as water-level limiter for steam boilers and (pressurized) hot-water installations on board of seagoing vessels, mobile offshore platforms or river boats. Water level limiters switch off the heating when the water level falls below the set minimum level (low water).

Media Library

English
PDF - Installation instructions

GESTRA product range - technical information

Steam traps and valves · electronic controls · automation special equipment and vessels for heat recovery

Media Library

English
PDF - Sales brochure

819743 Electropneumatic smart positioner SP500

The SP500 smart valve positioner is loop powered from a 4 - 20 mA input signal to provide accurate adaptive positional control of pneumatic actuated linear and quarter turn valves. Precise control is maintained through valve position feedback that automatically varies the pneumatic output pressure to overcome the effects of stem friction and flow forces to maintain desired valve position. Indication of valve position is provided through a continuous digital display of % travel.

Media Library

English
PDF - Installation instructions

Double Swing Check Valve BB 1 BB 2 BB 3

The equipment prevents the backflow of liquids or gases in pipes. The equipment can be installed in horizontal and vertical pipes. If the equipment is mounted in a vertical pipe the flow must normally be from bottom to top. If springs of type 5 VO are used, the equipment can also be installed in vertical pipes with downward flow. This kind of installation (vertically downward flow) is only possible with equipment up to DN 500.

Media Library

English
PDF - Installation instructions